Parcel: 140443060


Addresses:

6017 E CAMPOLINA TR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Permit Number - TC-MDP-0324-00297

Inspection Description - COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 10/3/24: Thermostat shall be no higher than 54" above finish grade, strap required at living room GLB, pex requires 12" clearance from can light, kitchen hood duct must be properly installed in wall, block registers on three sides at entrance, secure NM cable. 12" from fixture, seal penetrations at vapor barrier.
10/07/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Leak at 3" ABS line in downstairs bathroom. Re secure cs16 strap in closet at entry. 10/72024
10/08/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required Per previous notes. Leak at 3" ABS line. 10/8/2024
10/10/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 10/3/24: Thermostat shall be no higher than 54" above finish grade, strap required at living room GLB, pex requires 12" clearance from can light, kitchen hood duct must be properly installed in wall, block registers on three sides at entrance, secure NM cable. 12" from fixture, seal penetrations at vapor barrier.

Leak at 3" ABS line in downstairs bathroom. Re secure cs16 strap in closet at entry. 10/72024

Per previous notes. Leak at 3" ABS line. 10/8/2024

10/10/24:per previous notes leak at first floor bathtub. Pour back required underneath bathtub.
10/15/2024 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed 10/15/24 corrections made