Inspection History Details
Inspection Status: Canceled
Inspection History: COT - RSEL - Grounding/Bonding
Permit Number - TC-MDP-0324-00297
Inspection Description - COT - RSEL - Grounding/Bonding
Inspection Status - Canceled
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/01/2024 | COT - RSEL - Grounding/Bonding | Canceled | Canceled per contractor. 10/1/2024 | |
10/03/2024 | COT - RSEL - Grounding/Bonding | Re-inspection required | 10/3/24: Thermostat shall be no higher than 54" above finish grade, strap required at living room GLB, pex requires 12" clearance from can light, kitchen hood duct must be properly installed in wall, block registers on three sides at entrance, secure NM cable. 12" from fixture, seal penetrations at vapor barrier. Properly secure Ufer ground | |
10/07/2024 | COT - RSEL - Grounding/Bonding | Passed |