Inspection Status: Re-inspection required
Inspection History: COT - RSPL - Plumbing Final
Permit Number - TC-MDP-0324-00294
Inspection Description - COT - RSPL - Plumbing Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/24/2024 | COT - RSPL - Plumbing Final | Re-inspection required | Attic access does not give the proper clearances to get to unit. Large hole through wall at sliding glass door and disconnect boxes at units. Electrical panel needs knock out seals underneath. Level out condenser unit and provide 3" of clearance from dirt. Buried receptacles in both north bedrooms. Switch for fan in laundry room is defective. Paint exterior pipes. Cut TMP line 6" from earth. 9/24/2024 | |
10/08/2024 | COT - RSPL - Plumbing Final | Passed | Corrections were made. 10/8/2024 |