Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Underground 

Permit Number - TC-MDP-0324-00286

Inspection Description - COT - RSEL - Electrical Underground 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/23/2024 COT - RSEL - Electrical Underground  Re-inspection required 8/23/24: Bent dowels at garage hold downs not per plan, wrap all plumbing pipe, properly support UFER off of form, stepped down at hold downs require 18" depth at hold downs, PT cable exposed more that 12" at stationary end.
08/27/2024 COT - RSEL - Electrical Underground  Passed 8/27/2024 corrections have been made