Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0324-00281

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/20/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing king studs at door entry and SGD. Add stud underneath three ply girder. Add straps to all headers to studs. Porch and patio areas. Add shot pins to interior walls. Nail off rsp south wall of home. Add anchor bolt at primary room. 8/21/2024
08/26/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Corrections were made. 8/26/2024