Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Preslab
| Date |
Description |
Inspector |
Results |
Comments |
| 09/13/2024 |
COT - RSBU - Preslab |
|
Re-inspection required |
9/13/24: approved plans not on site, damaged sheathing at pt tendons must be addressed, rebar must have a minimum clearance from earth of 3", pad must be properly compacted, all plumbing encased in concrete must be properly wrapped. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. |
| 09/17/2024 |
COT - RSBU - Preslab |
|
Re-inspection required |
Pad is loose. Needs compaction. Provide reinforcement to tubs. 9/17/2024 |
| 09/19/2024 |
COT - RSBU - Preslab |
|
Passed |
Approved. Okay for concrete placement. 9/19/2024 |