Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0324-00270

Parcel: 138102040


Addresses:

140 E DREXEL RD

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
10/03/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Provide anchor bolts at breaks in plates and those that are out of the center third of bottom plate. Add cs16 straps from 4x6 beam to post. Add cs16 straps to tie in interior walls to exterior. Both sides. 10/3/2024
10/04/2024 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed