Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 138102060


Addresses:

180 E DREXEL RD


Inspection Status: Partial Pass

Inspection History: RSBU - Building Progress

Permit Number - TC-MDP-0324-00268

Inspection Description - RSBU - Building Progress

Inspection Status - Partial Pass

Date Description Inspector Results Comments
08/15/2024 RSBU - Building Progress Partial Pass 8/15/24: screen wall footing reinforcement between unit per plan ok to proceed.
08/26/2024 RSBU - Building Progress Partial Pass 8/26/24: first lift at 4’ at 8”CMU screen wall passed ok to grout. ok to proceed
08/30/2024 RSBU - Building Progress Partial Pass 8/30/24: 8” CMU wall at back porch reinforcement per plan ok to grout,
09/06/2024 RSBU - Building Progress Partial Pass 9/6/24: 1/2” GYP BOARD at demising wall fastened per schedule ok to proceed with fire wall.
11/19/2024 RSBU - Building Progress Re-inspection required 11/19/24: 5D screws required at shear walls. fasteners missing throughout at field and edges of gypsum board, properly secure shower mixing valves in master bedroom, seal chase at master bathroom behind shower wall,