Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141450770

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0323-00762

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/30/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Loose anchor bolts. Tighten anchor bolts throughout, sister stud at back shear wall, add nails to studs at back shear wall, missing rsp4 clips top plate right side of house.
12/08/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed