Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141450770

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0323-00762

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/30/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Loose anchor bolts. Tighten anchor bolts throughout, sister stud at back shear wall, add nails to studs at back shear wall, missing rsp4 clips top plate right side of house.
12/08/2023 COT - RSBU - Exterior Clips/Sheathing  Passed