Parcel: 141434780

Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0323-00755

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
02/13/2024 COT - RSBU - Exterior Clips/Sheathing  Passed
12/01/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Use proper wood structural material for front house shear wall, plans call for 2-2x8 header for front header of front porch, optional great room layout calls for 2-2x8 header for back porch entrance. Both options call to be supported by 2x6 studs., 2-2x6 studs at back porch columns holding up 13.5” GLB installed incorrectly, loose anchors bolts. Tighten all anchor bolts throughout, Truss A05 missing rat run, over spanned studs at interior wall.
12/08/2023 COT - RSBU - Exterior Clips/Sheathing  Partial Pass Loose anchor bolts. Tighten anchor bolts throughout. Partial-pass. Check at intermediate.