Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0323-00754
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/01/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Front porch header calls for a 2-2x8 header, optional great room layout calls for 2-2x8 header for back porch entrance. Both options call to be supported by 2x6 studs., missing second A14 GT, missing lateral bracing truss A06 A05, loose anchors bolts. Tighten all anchor bolts throughout. | |
| 12/08/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | missing lateral bracing truss A06 A05, loose anchors bolts. Tighten all anchor bolts throughout. | |
| 12/28/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |