Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0323-00726
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/27/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Column at right side of garage must be 4x8, missing 2-2x4 studs for post above, missing 2 2x4 studs at each bearing point for girder truss behind garage, missing rsp4 clip at right side of garage. | |
| 11/29/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | Missing 2 2x4 studs for post above. No plans. | |
| 12/04/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 12/4/23: 2x4 studs have been added were needed at bearing walls. |