Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - TC-MDP-0323-00692
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/19/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is in place, rebar reinforcement is installed per plans, UFER Ground is in place, shear wall hold downs are in place per plans, masa clips are properly installed, underground electrical for kitchen island is in place, and all underground plumbing pipes are properly wrapped with foam wrap. Okay to pour concrete for slab and footings. |