Inspection History Details
Inspection Status: Partial Pass
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0323-00678
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Partial Pass
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/24/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Partial Pass | 5/24/23: missing king studs at both side of entrance opening, anchor bolts required to be placed in the middle third of base plate, anchors required within 12" of end-of-plate. MASA with both legs up are not allowed at any location. | |
| 05/26/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 5/24/23: missing king studs at both side of entrance opening, anchor bolts required to be placed in the middle third of base plate, anchors required within 12" of end-of-plate. MASA with both legs up are not allowed at any location. 5/26/23: Missing RSP4 required every other stud per plans. Missing Anchor bolt where MASA clips have two legs up. |
|
| 05/30/2023 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |