Parcel: 13630138A

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0323-00672

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
07/21/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 7/21/23: all shear wall 11 and greater require 3"x3" plates, shear wall at garage missing nailing to bottom plate, anchor bolt spacing at shear wall 11 is 23" on center. Missing anchor bolt at shear wall in master at bottom plate.
07/25/2023 COT - RSBU - Exterior Clips/Sheathing  Passed