Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0323-00663
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/11/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Add anchor bolts per shear wall schedule and 12” at breaks. Add studs underneath double girders and girders in bedroom west of garage. Nail off h25 clip in bedroom west of garage. 9/11/2023 | |
09/13/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |