Permit: TC-MDP-0226-00056

Parcel: 141155800


Addresses:

10014 E LEBARON

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Interior Shear Bracing 

Date Description Inspector Results Comments
09/14/2026 COT - RSBU - Interior Shear Bracing  Re-inspection required 9/14/26: Fasteners shall be no closer than 3/8" from edge of drywall (Throughout), fasteners shall penetrate no more than 1/8" into drywall (throughout), SW1 at BDRM 2 and Primary W.I.C (spacing must be 7" o.c), patch damaged drywall throughout, Drywall shall be spaced no more than 1/2" from floor to bottom plate, 1/8" max spacing at joints between drywall panels.
09/15/2026 COT - RSBU - Interior Shear Bracing  Re-inspection required 9/15/26: see previous notes regarding drywall spacing from floor to bottom plate. I noted several sections of drywall upstairs that are spaced between 1" to 2". Make corrections and reschedule when ready.
09/17/2026 COT - RSBU - Interior Shear Bracing  Passed 9-17-26. All corrections have been made OK to proceed