COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-9-25: add nails to exterior sheathing and at interior shear walls at marked locations, add shot pins to marked location and nail those marked in red flush to sill plate, add H-25's 3-pt bearing girder truss at garage/ bedroom 2, beam to post connections require 10 nails above/below interconnecting points-see Detail S5.1-6., loose roof panel at master suite bathroom.
06/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 6-10-25: exterior clips/sheathing approved
06/10/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-10-25: missing h-25's at 3pt bearing girder truss at garage/bedroom 2.