Permit: TC-MDP-0225-00115

Parcel: 140444470


Addresses:

5935 E JAYDEN LN

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in.

Date Description Inspector Results Comments
06/18/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Re-inspection required 6/18/25: lath incomplete, Nail plates required at all rough-ins with 1 1/4" of 2x, thermostat shall be no higher than 48" AFF, seal penetration through vapor barrier at kitchen pantry, support flex duct at ceiling, seal penetration through vapor bar at entry and under stairs, fire block pen at stairs, drywall screws cannot be used for fan fixtures, strap at DWV not properly secured at 2nd story east wall, properly secure thermostat in wall at south west wall.
06/23/2025 COT - RSBU - Residential Intermediate may include Framing, Electrical, Plumbing, HVAC and/or Mechanical work. Only one inspection may be attached for all trades for final rough-in. Passed Approved. Corrections were made. 6/23/2025