Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141461860


Addresses:

9571 E WYNALDA DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0225-00100

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/12/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 6-12-25: missing nails at bedroom 2 shear wall-check shear wall schedule @4" o.c., add anchor bolts and 3x3" washers at marked locations for shear walls, add additional anchor bolts at marked locations,add nails to marked location at sheathing for bedroom 3-cannot over-penetrate nails more than 1/8", install larger cs strap with 10 nails above/below interconnecting points at post to beam -detail 317 at back patio, missing king stud at sw11 east side of great room, loose roof panels at center of garage and at marked area of master bedroom. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED.
06/16/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Partial Pass Partial pass pending anchor bolt @west side of house to be checked at intermediate
06/30/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed 6/30/25 corrections made