Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0225-00096
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/12/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 6-12-25: replace or sister damaged stud on west side of great room and add rsp4, sister or replace stud on west side of bedroom 3 along with stud on east side of garage. Shear wall at bedroom 3 requires nails 12" in the field-add nails, missing nails at master bedroom shear wall along joints/edges-4" o.c., loose roof panels throughout to include garage and bedrooms-remove all items from loaded roof to conduct a proper inspection, add shot pins to red marked (x) locations. | |
| 06/23/2025 | COT - RSBU - Roof Nailing | Re-inspection required | 6/23/25 nailing and roofing still need correction | |
| 06/24/2025 | COT - RSBU - Roof Nailing | Canceled | ||
| 06/25/2025 | COT - RSBU - Roof Nailing | Passed | 6/25/25 corrections made |