Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0225-00092
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 10-8-25: add anchor bolts to marked locations, add shot pins on non bearing walls at 32" o.c. And 24" o.c. For interior load bearing walls-shot pins are required within 6" at the end/both sides of sill plates, add nails 8" o.c. At joints to garage shear wall. STOPPED INSPECTION-ADDITIONAL ITEMS MAY BE ADDED. | |
| 10/09/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Not Ready | Add A35 and H25 clip at back patio East end. Add shot pins and anchor bolt at marked areas. Add king stud at primary shower window. Add bracing to truss A1E. Add 2 nails every 24” at ledger in bedroom 3. Add shims and H25 clips at truss A3 bearing points. (At entry) 10/9/2025 | |
| 10/10/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 10.10.25 corrections made |