Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0225-00086
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/28/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 28 March 25 1. Shear wall sw11 requires AB at 23” O.C. And require 3x3 plate washers. 2. Masa clips needs to be minimum 4” from splices on sill plate. 3. Compromised 2x4 just off hallway 4. Various broken/cracked truss. Marked on the ground with Blue marker. |
|
| 04/01/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 1 April 25 No corrections made. |
|
| 04/17/2025 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed |