Parcel: 141461250


Addresses:

9512 E MEOLA DR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Permit Number - TC-MDP-0225-00086

Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
03/28/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 28 March 25
1. Shear wall sw11 requires AB at 23” O.C. And require 3x3 plate washers.
2. Masa clips needs to be minimum 4” from splices on sill plate.
3. Compromised 2x4 just off hallway
4. Various broken/cracked truss. Marked on the ground with Blue marker.
04/01/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required 1 April 25
No corrections made.
04/17/2025 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed