Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0225-00086

Parcel: 141461250


Addresses:

9512 E MEOLA DR

Inspection Status: Failed

Inspection History: ENGR Engineering Final

Date Description Inspector Results Comments
07/29/2025 ENGR Engineering Final Failed Sewer clean out in driveway: Rebar safety cap placed over pipe end with no collar or correct cap.
08/20/2025 ENGR Engineering Final Failed 8/20/25
Still no glued collar or cap under cover in driveway.
See Picture attached.
Second time this has failed for the same reason. Reinspection Fee required. Pay invoice prior to scheduling Engineering Final again.
08/22/2025 ENGR Engineering Final Passed