Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0225-00084

Parcel: 12509115A


Addresses:

240 N STEWART AV

Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Underground 

Date Description Inspector Results Comments
08/22/2025 COT - RSEL - Electrical Underground  Re-inspection required 8.22.2025
Tracer wire required on gray water pipes outside slab, DWV not completely under test, electrical conduit not complete in trench and above grade needs to be Scheduled 80, clear trench of heavy rocks. Water line not under test.
08/25/2025 COT - RSEL - Electrical Underground  Passed 8.25.2025
1x 2" sub panel conduit and 2x 1" solar conduits running about 40'. Okay to backfill with shading.