Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0224-00264
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/30/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing 2-2x4 studs for GT at entry on stairs side, missing 2-2x4 T for great room window, shear wall 8 missing anchor bolts, | |
06/04/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 2-2x4 T for great room window per plans. | |
06/21/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed | Missing 2-2x4 studs for GT at entry on stairs side, missing 2-2x4 T for great room window, shear wall 8 missing anchor bolts, 2-2x4 T for great room window per plans. 6/21/24: passed/ |