Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140443110


Addresses:

6042 E CAMPOLINA TR


Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0224-00264

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
05/30/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing 2-2x4 studs for GT at entry on stairs side, missing 2-2x4 T for great room window, shear wall 8 missing anchor bolts,
06/04/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 2-2x4 T for great room window per plans.
06/21/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Missing 2-2x4 studs for GT at entry on stairs side, missing 2-2x4 T for great room window, shear wall 8 missing anchor bolts,

2-2x4 T for great room window per plans.
6/21/24: passed/