Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0224-00259
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/01/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is properly installed and spaced, required rebar reinforcement is in place per plans, all plumbing pipes are properly wrapped for protection, underground electrical for kitchen island and floor outlet in great room is installed, Ufer ground rebar is installed. Okay to pour concrete for footings and slab. |