Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | Missing 2-2x4 studs for post above at back garage area, missing 4x6 post to support 4x12 beam at entry, missing 2-2x6 and 2-2x4 studs to support GT at entry, add blocking between floors to allow continuous load transfer from second to first floor at all bearing posts, missing 4x6 post at back porch, missing 2-2x4T at great room window, missing anchor bolts at perimeter of house. Stopped inspection. More items may be added. | |
05/31/2024 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 2-2x4 studs for post above at back garage area missing blocking between floors, missing 2-2x4T at great room window, missing anchor bolts at perimeter of house, missing h2.5 clips at left side of house and back side of house. | |
06/04/2024 | COT - RSBU - Exterior Clips/Sheathing | Passed |