Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Permit Number - TC-MDP-0224-00246
Inspection Description - COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
Inspection Status - Re-inspection required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/21/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 6/21/24: anchor bolt spacing not per plan throughout, h2.5 clip missing at truss, masa clip at back porch must be properly fastened, strap at beam missing at back porch, roof nailing not per schedule throughout. | |
| 07/05/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Re-inspection required | 7/5/24: missing nailing at h25 at back of house. Anchor bolts not to schedule at back of house excessive masa legs up need anchor bolts at break in plates. Check roof nailing | |
| 07/09/2024 | COT - RSBU - Exterior/Interior Clips/Sheathing/Framing | Passed | 7/9/2024 corrections were made. |