Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0224-00246
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/21/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 6/21/24: anchor bolt spacing not per plan throughout, h2.5 clip missing at truss, masa clip at back porch must be properly fastened, strap at beam missing at back porch, roof nailing not per schedule throughout. | |
07/05/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 7/5/24: missing nailing at h25 at back of house. Anchor bolts not to schedule at back of house excessive masa legs up need anchor bolts at break in plates. Check roof nailing | |
07/09/2024 | COT - RSBU - Roof Nailing | Passed | 7/9/2024 corrections were made. |