Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/04/2024 | ENGR Engineering Final | Re-inspection required | Gate missing Clean out in frt. yard needs to be cut down. Clean outs on left side collars not glued down. Grade at AC unit needs to be repaired Water holding on right side and rear yard Brick missing in driveway Dumpster needs to be moved from front of home Cinder block rubble on left side rear of home needs to be cleaned up |
|
11/06/2024 | ENGR Engineering Final | Not Ready | Pictures are attached. Someone filled one of the 2” clean outs with rocks. Rest is all in the pictures. |
|
11/14/2024 | ENGR Engineering Final | Passed | CO Ready |