Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 140443710


Addresses:

6006 E FALCONRY TR


Inspection Status: Canceled

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0224-00231

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Canceled

Date Description Inspector Results Comments
04/19/2024 COT - RSBU - Exterior Clips/Sheathing  Canceled Cancelled per Tito.
04/22/2024 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing shear wall at back of house, add toe nailing from stud to sole plate to 2x6 shear wall stud by front door entrance, toe nailing stud to sole plate needed by dining room area, cut 2x4 sole plate at back porch, over spalled masa clip at back porch column, missing clips at back porch, anchor bolt needed at back of house, missing clips and strap columns front porch, column to post connections missing Simpson ST2215 straps at front and back porch per SD3 details 28, 29, 30.
04/24/2024 COT - RSBU - Exterior Clips/Sheathing  Passed