Inspection Status: Passed

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0224-00189

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Passed

Date Description Inspector Results Comments
06/14/2024 COT - RSBU - Exterior Clips/Sheathing  Passed Plywood sheathing for exterior shear walls is properly nailed per plan requirements. All bottom plates are secured to the concrete floor with cut nails, shot pins, poured in j-bolts, or titanium bolts. All shear wall hold downs are properly secured with nails to the studs. Okay to proceed with rough-in of mechanical, electrical, and plumbing work.