Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSEL - Grounding/BondingĀ
Permit Number - TC-MDP-0224-00189
Inspection Description - COT - RSEL - Grounding/BondingĀ
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/31/2024 | COT - RSEL - Grounding/BondingĀ | Passed | Concrete forms are set, post tension cabling is properly placed, shear wall hold downs and masa clips are secured to the form per the plan, subsoil is properly compacted, underground electrical for kitchen island is installed, all plumbing pipes are properly wrapped for protection, and Ufer ground rebar is properly installed in bottom of footer. Okay to proceed with concrete pour. |