Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Passed

Inspection History: COT - RSEL - Grounding/BondingĀ 

Permit Number - TC-MDP-0224-00189

Inspection Description - COT - RSEL - Grounding/BondingĀ 

Inspection Status - Passed

Date Description Inspector Results Comments
05/31/2024 COT - RSEL - Grounding/BondingĀ  Passed Concrete forms are set, post tension cabling is properly placed, shear wall hold downs and masa clips are secured to the form per the plan, subsoil is properly compacted, underground electrical for kitchen island is installed, all plumbing pipes are properly wrapped for protection, and Ufer ground rebar is properly installed in bottom of footer. Okay to proceed with concrete pour.