Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Preslab
Permit Number - TC-MDP-0224-00188
Inspection Description - COT - RSBU - Preslab
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/22/2024 | COT - RSBU - Preslab | Passed | Concrete forms are set, post tension cabling is properly spaced and on chairs to maintain separation from earth, masa clips are installed and spaced properly, shear wall hold downs are installed per plan, underground electrical is installed for kitchen island, additional rebar is in place per plans, Ufer ground is installed on left side of garage, and all plumbing pipes are properly wrapped with foam for protection from concrete. Okay to pour slab and footings. |