Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSBU - Excavation/Rebar/Zoning
Permit Number - TC-MDP-0224-00186
Inspection Description - COT - RSBU - Excavation/Rebar/Zoning
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/24/2024 | COT - RSBU - Excavation/Rebar/Zoning | Passed | Concrete forms are set, post tension cabling is in place per plans, shear wall hold downs and masa clips are installed per plan, underground electrical for kitchen island is installed, rebar reinforcement is placed per plan, Ufer ground is installed on side of garage, and all plumbing pipes are properly wrapped for protection. Okay to pour concrete for slab and footings. |