Inspection Status: Re-inspection required
Inspection History: COT - RSEL - Electrical Final
Permit Number - TC-MDP-0224-00169
Inspection Description - COT - RSEL - Electrical Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/22/2024 | COT - RSEL - Electrical Final | Re-inspection required | 8/22/24: pressure relief termination must be 6" above grade. SWG meter not hooked up, 3" clearance around hvac condenser to grade, HVAC being over amped (30amp max),post tension tag required at hose bib, remove covers off of smoke detectors, electrical at garage not complete, receptacle spacing at counter exceeds 24", from edge of counter. Water closet must be caulked, clean out required at A.V.V., tempered glass required at shower per plans, | |
08/29/2024 | COT - RSEL - Electrical Final | Passed | Corrections were made. 8/29/2024 |