Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-0224-00169
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
RSBU - Building Final | Re-inspection required | 8/22/24: pressure relief termination must be 6" above grade. SWG meter not hooked up, 3" clearance around hvac condenser to grade, HVAC being over amped (30amp max),post tension tag required at hose bib, remove covers off of smoke detectors, electrical at garage not complete, receptacle spacing at counter exceeds 24", from edge of counter. Water closet must be caulked, clean out required at A.V.V., tempered glass required at shower per plans, | ||
08/29/2024 | RSBU - Building Final | Passed | Corrections were made. 8/29/2024 |