Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0224-00167
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/10/2024 | COT - RSBU - Roof Nailing | Re-inspection required | 12/10/24: Shot pins required at interior walls, RSP4 Clips missing throughout, MASA clips must be installed per manufacturer specifications (nails missing at MASA Clips), More than 1 in 3 MASA Clips with one leg up along wall line. STOPPED INSPECTION MORE ITEMS MAY BE ADDED. | |
12/12/2024 | COT - RSBU - Roof Nailing | Passed | 12/12/24 corrections made |