Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Roof Nailing
Permit Number - TC-MDP-0224-00162
Inspection Description - COT - RSBU - Roof Nailing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/11/2024 | COT - RSBU - Roof Nailing | Re-inspection required | Missing king studs at windows great room area and bedroom. Missing h25 clips at bearing points. Plans call for x2 2x6's at back patio supporting GLB. 7/11/2024 | |
07/15/2024 | COT - RSBU - Roof Nailing | Passed |