Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior Clips/Sheathing
Permit Number - TC-MDP-0223-00606
Inspection Description - COT - RSBU - Exterior Clips/Sheathing
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/18/2023 | COT - RSBU - Exterior Clips/Sheathing | Re-inspection required | 9/18/23: Attach king studs to trimmer studs in closet opening in the foyer, install H2.5 at all truss bearing points as 16d nails can not attach thru shims into top plate. | |
09/21/2023 | COT - RSBU - Exterior Clips/Sheathing | Passed |