Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0223-00594

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
11/03/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Missing king studs at each end of family room window, missing anchor bolts at shear walls. Shear wall anchor bolts must be installed with 3x3” plate washers per plans, anchor bolts missing at perimeter of house.
11/07/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Not ready.
11/09/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Shear wall anchor bolts must be installed with 3x3” plate washers per plans, anchor bolts missing at perimeter of house. Anchor bolts loose. Tighten all anchor bolts throughout.
11/13/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required Shear wall anchor bolts to be installed with minimum 3x3” plate washers per plans, anchor bolts still loose, STHD14 hold downs over spalled at front of house.
11/17/2023 COT - RSBU - Exterior Clips/Sheathing  Passed