Parcel: 141433270

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior Clips/Sheathing 

Permit Number - TC-MDP-0223-00588

Inspection Description - COT - RSBU - Exterior Clips/Sheathing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/14/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required
06/16/2023 COT - RSBU - Exterior Clips/Sheathing  Re-inspection required 6/14/23: Multiple Holddowns are over spalled, missing anchor bolts, missing coil strap cs16x5', fire block panels need to be 3/4" min. at dead space, vertical fire block missing at upstairs front wall as well as ceiling, shear wall at second floor needs more nails, sole plate nails not per schedule.
6/16/23: Multiple Holddowns still over spalled, shear wall anchor bolts not per schedule, missing coil strap cs16x5, vertical fire block missing at upstairs front wall as well as ceiling.
06/21/2023 COT - RSBU - Exterior Clips/Sheathing  Passed