Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Parcel: 141433280

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Roof Nailing 

Permit Number - TC-MDP-0223-00580

Inspection Description - COT - RSBU - Roof Nailing 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
06/12/2023 COT - RSBU - Roof Nailing  Re-inspection required 6-12-23: No ladder for roof access.
06/13/2023 COT - RSBU - Roof Nailing  Re-inspection required 6-13-23: 1-Nail where marked in Red. 2-Staples are turned perpendicular to framing members; must be parallel per ESR-1539. 3-Remove all shiners and re-nail to hit the framing members.
06/16/2023 COT - RSBU - Roof Nailing  Re-inspection required 6-12-23: No ladder for roof access.

6-13-23: 1-Nail where marked in Red. 2-Staples are turned perpendicular to framing members; must be parallel per ESR-1539. 3-Remove all shiners and re-nail to hit the framing members.

6/16/23: Nails/staples still missing on roof.
06/21/2023 COT - RSBU - Roof Nailing  Passed