Inspection Status: Re-inspection required

Inspection History: COT - RSEL - Electrical Final 

Permit Number - TC-MDP-0223-00566

Inspection Description - COT - RSEL - Electrical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/22/2023 COT - RSEL - Electrical Final  Re-inspection required Base of a/c. must be 3" above grade, non-metallic conduit at a/c must be secured, thermostat to be 54" above floor per plans, provide plans, add outlet to right side of countertop at the right side of the range per 2018 IRC E3901.4.
08/28/2023 COT - RSEL - Electrical Final  Passed