Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSME - Mechanical Final 

Permit Number - TC-MDP-0223-00566

Inspection Description - COT - RSME - Mechanical Final 

Inspection Status - Re-inspection required

Date Description Inspector Results Comments
08/22/2023 COT - RSME - Mechanical Final  Re-inspection required Base of a/c. must be 3" above grade, non-metallic conduit at a/c must be secured, thermostat to be 54" above floor per plans, provide plans, add outlet to right side of countertop at the right side of the range per 2018 IRC E3901.4.
08/28/2023 COT - RSME - Mechanical Final  Passed