Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/14/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing cs16 straps in garage, missing hangers at front porch, missing blocking panels above bearing/shear wall per plans, missing (2) 2x4 on each side of back porch pillars, add stud to right side of bearing point in bed. 3. Studs are not bearing full load for G410 (3-ply), add 3 studs to left side of bearing point in bed. 3 for G410 3-ply per plans, missing anchor bolts at shear walls, add nails to stud at second floor back shear back, add nails to masa clips at porch pillars, add anchor bolt to front porch pillar,
08/21/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Missing cs16 straps in garage, missing blocking panels above bearing/shear wall per plans.
08/23/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed Missing cs16 straps in garage