Inspection History Details
Inspection Status: Re-inspection required
Inspection History: RSBU - Building Final
Permit Number - TC-MDP-0223-00557
Inspection Description - RSBU - Building Final
Inspection Status - Re-inspection required
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/14/2024 | RSBU - Building Final | Re-inspection required | Missing panel labeling “for future solar use” per T103.9, missing anti-theft caps at bottom of A/C unit, pressure relief valve sticking outside of drip pan at WH, Range must have a minimum 24” vertical clearance to non-combustibles per G2447.5, outlet under kitchen sink not properly installed, inclusive home design. Thermostats to be at a maximum of 54” OC above floor, no ladder for attic access. | |
03/08/2024 | RSBU - Building Final | Passed |