Inspection Status: Re-inspection required
Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing
| Date |
Description |
Inspector |
Results |
Comments |
| 07/18/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Re-inspection required |
7/18/23: missing RSP4 clips throughout, missing rsp5 clips at kitchen, missing htt4 holddown at master bedroom shear wall, missing king stud at back porch, missing anchor bolts throughout, missing anchor bolts at shear wall, missing 3x3 plates at shear wall, missing clips at headers, missing stud at back porch column. |
| 07/20/2023 |
COT - RSBU - Exterior/Interior Clips/Sheathing/Framing |
|
Passed |
7/20/23: missing one anchor bolt marked with x in red felt pen will check at intermediate |