Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: TC-MDP-0223-00450

Parcel: 141431600


Addresses:

7712 S VIA PERFECTA

Inspection Status: Re-inspection required

Inspection History: COT - RSBU - Exterior/Interior Clips/Sheathing/Framing

Date Description Inspector Results Comments
08/02/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Re-inspection required Hangers missing at porch truss P41, missing king stud at each end of master suite window, ridge blocking missing at hip, missing CS16x6 strap for glulam beam between kitchen and master bath, tighten hold down at garage shear wall, nails missing at great room shear wall, add nails to loose stud in garage, nail rsp4 clip by garage, rsp4 clip missing at window by great room, anchor bolts missing at shear walls and perimeter of house.
08/08/2023 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed